Mixing by aspiration—mixing of sample by aspiration instead of shaking makes sure homogeneity of your sample and maintains cell viability

The CytKick Max Autosample includes a Strengthen method that allows speedier sample processing, along with passive cooling for many plates/racks. A CytKick Max Accessory Kit is incorporated which contains 4 accent plates: two cooling plates and two tube adaptors, in addition to a Max dongle important. A computer is just not bundled Using the autosampler due to the fact a person is supplied with the cytometer.

To prevent probe crashes, which may need high-priced probe alternative, the CytKick Max Autosampler quickly performs a probe self-calibration to help make sure steady positioning in the probe in just about every perfectly. The self-calibration verifies correct perform from the probe, minimizes variability in probe positioning with time to avoid failures in the course of plate runs, and assists improve trustworthiness around the lifetime of the technique.

As opposed to other plate loaders that mix samples by shaking, which can not assure homogeneity on the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing although preserving sample viability and resulting in dependable facts with CVs below 10% through the plate. The CytKick Max Autosampler also has a mild mix manner for fragile cell strains.

The autosampler’s indicator lights and warning units are created to make certain that a person who's got walked away from the procedure can easily begin to see the program position continually.

To maintain process versatility, the handbook sample probe perkin elmer autosampler is always available even when the loader is current, and switching between tubes and plates is detected by means of software program and would not call for additional consumer intervention.

The CytKick Max Autosampler was designed to lessen system down time. Automated sampling products are often tormented by clogging or probe crashes. The Clever Probe, using a two hundred-micron diameter that is more substantial than most probes out there inside the marketplace, minimizes instances of clogging.

The intuitive application will allow fast Finding out and data analysis. By way of example, a warmth map see makes it possible for swift screening and affirmation of samples though the instrument is acquiring information.

Effortless transition—no disassembly, no added QC, no reboot expected for conversion concerning plates and tubes

The CytKick Max Autosampler has two options for processing samples in a higher-throughput atmosphere: large-throughput mode and Increase mode.

Self-calibration from the probe also enables the autosampler to become effortlessly moved, so it can be shared between multiple devices.

The instrument structure and software package ended up designed with client ease-of-use in your mind. The CytKick Max Autosampler has fluidic bottles with sensors that notify the user in the event the fluids should be replaced.

Autocleaning of autosampler is done during the instrument shutdown system for that reason no further user techniques are essential to maintain process.